Yes, if "6 fittings" means a fitting sized for 3/8-inch nominal copper tubing, which is what "6" denotes in the trade's shorthand. Brass compression fittings are the standard pairing for nominal 3/8-inch copper, and the brass body, brass or plastic olive, and brass nut are designed as one system.
The answer changes if "6" refers to something else, such as a 6 mm metric fitting, a 6-inch pipe, or a part number, because compression compatibility turns on three things: tube outside diameter, fitting thread standard, and the material the fitting is grabbing.
What "6 fittings" actually refers to
In North American plumbing shorthand, a "6 fitting" is a 3/8-inch fitting, because the old sizing convention assigned part numbers by eighths of an inch: "4" is 1/2 inch, "5" is 5/8 inch, "6" is 3/8 inch, and "8" is 1 inch. That shorthand survives mainly in refrigeration and appliance work, where 3/8-inch copper is common for ice makers, water lines, and small-diameter connections.
A brass compression union labeled 6, or a 5/16 × 6 valve, is speaking that language.
Metric and fractional sizing do not line up. A fitting marked "6 mm" is sized for 6 mm outside-diameter tube, which is 0.236 inch, while 3/8 inch is 0.375 inch. Those two will not seal against each other, and forcing a 6 mm olive onto 3/8-inch tube, or the reverse, produces a joint that either won't enter the fitting body or won't compress.
Before buying anything, read the existing fitting's label and measure the tube's outside diameter with a caliper. If the measurement lands near 0.375 inch (9.5 mm), you're in fractional 3/8-inch territory; near 0.236 inch (6 mm), you're in metric territory.
The third reading of "6" is literal 6-inch pipe, which is a very different scale. Six-inch nominal pipe has an outside diameter of 6.625 inches, and compression fittings at that size are industrial, not the brass hardware-store type. Brass compression is used routinely up to about 2 inches in potable water and small refrigeration lines.
If your question is about 6-inch pipe, brass compression is the wrong family entirely; flanged, grooved, or welded connections are the normal choices.
Why brass and copper compression work together
Brass compression fittings are designed for copper tubing, and the seal depends on the copper deforming around a soft olive rather than on the brass threads. When you tighten the nut, it drives a tapered ring, usually called an olive or ferrule, into the fitting body. The ferrule compresses onto the tube, the body's cone seats against the ferrule, and the nut holds the assembly under tension.
The brass nut and body take the load; the copper tube takes the compression.
Brass is the usual body material because it machines cleanly, resists dezincification reasonably well in potable water when the alloy is appropriate, and is galvanically close enough to copper to avoid the aggressive corrosion you'd get from pairing copper with steel. In a copper-to-brass joint, there's no serious galvanic couple.
That's why a brass compression fitting on copper tube is a long-established, code-recognized connection for potable water in most jurisdictions, and why the same fittings appear throughout appliance and refrigeration work.
The compatibility question is therefore not "brass or copper" in the abstract. It's whether the specific fitting's bore, cone angle, and ferrule are matched to the tube's actual outside diameter and wall thickness, and whether the installation keeps the joint dry, clean, and correctly tightened. A 3/8-inch brass compression fitting on 3/8-inch soft copper is a matched pair.
A 3/8-inch brass compression fitting on 3/8-inch hard copper also works, but the harder tube demands more torque and a ferrule that can bite, and some thin-wall or heavily work-hardened tube is prone to cracking at the ferrule if overtightened.
Where compatibility breaks down
The most common failure isn't brass against copper; it's mismatched tube diameter or a ferrule that never seated. A fitting sold as "6" might be 3/8 inch in one catalog and 6 mm in another, and imported metric fittings look nearly identical to fractional ones.
The tell is the nut's thread and the body's bore: a 3/8-inch compression nut threads onto a 3/8-inch body, while a 6 mm nut is slightly smaller. Cross-threading a metric nut onto a fractional body feels tight immediately and will leak. Measure or read the stamp, don't eyeball.
Wall thickness matters too. Soft copper in 3/8-inch size is commonly available in several wall thicknesses, and a ferrule sized for one may not compress correctly on another. Very thin-wall tube can crush or split under a standard ferrule, while heavy-wall tube may resist the ferrule enough that the nut bottoms out before the seal forms.
If you're reusing an existing fitting, the old ferrule has already been compressed to the old tube; a new tube of a different wall thickness won't seal against it. Replace the ferrule with the tube.
Material pairing beyond copper is the other trap. Brass compression fittings are sometimes used on cross-linked polyethylene (PEX) or on plastic tubing with a stiffener insert, but that's a different fitting family, usually with a plastic or metal insert and a different nut design.
A standard brass compression fitting intended for copper is not a substitute for a PEX compression fitting, and using one on plastic tube risks cracking the tube at the ferrule. Likewise, brass against steel pipe is a galvanic couple; in a wet, long-lived installation, that joint corrodes, and dielectric unions or a different connection method are the safer route.
A practical compatibility check
The check is short and physical. Measure the tube's outside diameter with a caliper and compare it to the fitting's marked size. Confirm the fitting is labeled for the tube material you have, not just the diameter. Inspect the ferrule: a new brass or plastic olive should be undistorted and matched to the nut and body from the same set.
Hand-tighten the nut, then tighten with a wrench roughly one to one-and-a-quarter turns past finger-tight for a typical 3/8-inch brass fitting on soft copper, and stop as soon as resistance rises sharply; more is not better, and over-tightening is a common cause of split tube and crushed ferrule.
Then pressure-test before closing up. For potable water, that means charging the line and watching for weeping at the nut for several minutes, then rechecking after the system reaches normal pressure. A joint that seeps at first and "seals itself" is not sealed; it will weep again. For refrigeration or appliance lines, the test is a leak check with soap solution or an electronic detector, because a slow refrigerant leak is invisible and expensive.
Reuse deserves its own caution. A brass compression fitting's body and nut can often be reused if they're undamaged and clean, but the ferrule should be replaced whenever the tube is cut or replaced. Reusing a compressed ferrule on new tube almost never seals, because the ferrule has already taken a set to the old tube's diameter and surface.
If the old joint leaked, cut back past the deformed section of tube, deburr and clean the end square, and start with a fresh ferrule.
Brass versus other 3/8-inch connection options
For a 3/8-inch copper line, brass compression is one of several legitimate choices, and the right one depends on access, permanence, and the material on each side. The table below compares the common alternatives on criteria that actually change the decision.
| Option | Best for | Reusable? | Main limitation |
|---|---|---|---|
| Brass compression fitting | Accessible joints, appliance and refrigeration lines, repairs | Body and nut often; ferrule no | Needs correct tube OD and fresh ferrule; can leak if overtightened |
| Soldered copper fitting | Permanent potable water joints, concealed locations | No | Requires heat, flux, and skill; not for flammable or tight spaces |
| Push-to-connect fitting | Fast repairs, mixed-material transitions, tight access | Body yes, tube end must be clean and square | Relies on an O-ring; sensitive to tube surface and insertion depth |
| Flare fitting | Refrigeration and gas lines, repeated disassembly | Yes, with care | Needs a flaring tool and correct flare angle; not for potable water in all codes |
Brass compression's advantage is that it works on soft and hard copper, needs only two wrenches, and tolerates disassembly. Its weakness is that the seal is made by deformation, so the quality of the tube end and the torque you apply determine the outcome.
A soldered joint is more permanent and more forgiving of vibration once made, but it can't be done near flammable material or in a confined space without care, and it's a one-way connection. Push-to-connect fittings are the fastest route and handle copper-to-PEX or copper-to-brass transitions well, but the internal O-ring is the wear point, and a scratched or out-of-round tube end will leak.
For a 3/8-inch line feeding an ice maker or a humidifier, brass compression is a sound, inexpensive choice, and the fittings are widely stocked. For a concealed potable water run inside a wall, many plumbers prefer soldered or a listed push fitting, because a compression joint that weeps behind drywall is a costly failure.
The compatibility question is answered by the tube and the fitting, but the installation question is answered by where the joint lives and who will have to reach it later.
Getting the size and material right the first time
The safest path with "6 fittings" is to treat the number as a starting point, not a specification. Confirm whether the part is 3/8-inch fractional or 6 mm metric by measuring the tube and reading the fitting, and buy a ferrule and nut as a matched set rather than mixing brands.
Brass bodies from different makers usually interchange on the same thread, but ferrule geometry varies, and a mismatched olive is a common source of weeping joints.
If you're connecting to something other than copper, identify that material before choosing the fitting. Brass compression on copper is the well-established pairing; brass compression on plastic tube, steel pipe, or 6-inch pipe is a different problem with different answers.
Match the fitting family to the tube, keep the tube end square and burr-free, tighten to the point of firm resistance rather than maximum effort, and test under pressure before you call it done. That sequence resolves most of what "compatible" means for a 6 fitting, and it costs a caliper measurement and a few minutes of leak checking.