An above-slab radiant barrier can cut downward heat gain into a floor, but it is not a substitute for slab insulation and it does almost nothing against upward heat loss. The decisive factors are the direction of heat flow, whether the shiny surface faces an air space, and whether the assembly can dry.
"Am rad" here means a radiant barrier — a low-emittance sheet with a reflective aluminum surface, typically laminated to a substrate or bonded to a foam board. The phrase "under slab" covers two different jobs that get confused constantly: a sheet placed in or above the slab during a new pour, and a barrier retrofitted beneath an existing floor.
Each has a different physics problem, and only one of them is a true thermal barrier in both seasons.
What a radiant barrier actually does under or over a slab
A radiant barrier works by suppressing radiant heat exchange across an air space, not by blocking conduction the way foam or mineral wool does. Aluminum foil or a metallized film has low emittance, commonly cited by manufacturers around 0.03 to 0.05 for bare foil, which means it re-radiates very little of the heat it receives and instead reflects it back.
For that property to matter, the low-emittance surface must face an enclosed air space of roughly ¾ inch or more, and that air space must not fill with soil, gravel, concrete or standing water.
The practical consequence is directional. A shiny surface installed over a slab, facing up into a ventilated or at least air-spaced floor cavity, limits the radiant component of heat moving downward from a hot room into the cooler slab.
A sheet laid directly beneath a poured slab, sandwiched between concrete and compacted fill, has no air space on either side and behaves like a thin, low-R sheet of plastic with a foil skin. Concrete shrinks and bonds against it, and any trapped air gap is discontinuous and moisture-prone rather than a designed cavity.
In that configuration the barrier contributes negligible thermal resistance; its value is limited to moisture control and to stopping vapor movement if it is a proper vapor retarder.
That distinction matters because the foil is often sold and marketed as though emittance alone delivers an R-value. Emittance affects only the radiative fraction of heat transfer across a cavity. Roughly speaking, downgoing heat through an air space is a mix of radiation, conduction through the air, and convection; the barrier attacks only the first.
In a typical floor assembly the cavity's own R-value plus the flooring's R-value often dominate, so a barrier added to an already insulated cavity is a modest improvement, not a transformation.
Direction of heat flow decides whether it helps or hurts
In cooling-dominated climates, the heat load a slab creates is downward: hot outdoor air and sun-heated soil push heat toward a conditioned space, or a warm room pushes heat into a cooler slab. A radiant barrier with a low-emittance surface facing the warm side resists that flow.
In heating-dominated climates the dominant load reverses, and the same barrier offers little, because the mechanism it blocks — radiant exchange — is a relatively small part of a properly insulated floor's heat loss.
A room-side floor over a slab is also a specific case. A foil-faced surface directly under finished flooring with no cavity does not create a radiant barrier at all; it is just a facing. The barrier only performs when the assembly includes the air space and that space stays dry.
In humid or flood-prone situations the more important function of the same sheet may be as a vapor retarder, deliberately placed on the warm, humid side to keep moisture out of the insulation below.
There is a real seasonal risk in cold climates too: a low-emittance surface placed in the wrong position can trap moisture rather than stop heat. A foil-backed or foil-faced product installed as a vapor retarder must be on the correct side of the insulation for the climate, and the assembly must be able to dry in at least one direction.
Sealing a slab assembly on both faces with low-permeability materials is a recipe for a wet, slowly decaying floor.
Where the barrier goes in a new slab assembly
For a new pour, the useful place for a radiant barrier depends on whether you're targeting moisture or thermal performance.
- Directly under the slab: place a vapor retarder — a heavy, properly lapped polyethylene sheet or a rated under-slab membrane — over compacted, drained granular fill, then the slab. This controls rising moisture and soil gas. A foil-faced under-slab product can serve as the vapor retarder and add a little radiant resistance to the gravel-to-concrete gap, but the foil's low emittance is doing almost nothing once the slab is poured against it. The dominant value is moisture and radon control.
- Below the rigid foam and above the vapor retarder: if the floor must be insulated, put extruded polystyrene (XPS) or another rated rigid board in the assembly, with the vapor retarder below or above it according to the assembly's drying strategy. The foam — typically around R-5 per inch for XPS per manufacturer data sheets — does the real insulating. A foil facing on the foam is a minor extra.
- In the floor cavity above the slab: if there's a framed floor over a vented or encapsulated crawl space, a foil-faced barrier with an air space can genuinely resist downward heat. This is the configuration where radiant barriers are actually designed to work.
The mistake to avoid is treating the radiant barrier as the insulation layer. Rigid foam, spray foam, or a properly installed batt in a framed cavity provides the R-value; the foil provides an emittance benefit only in a cavity.
Retrofitting under an existing floor
If the slab is already poured and you're considering a barrier beneath a finished floor, the options are constrained. You can sometimes install foil-faced rigid board over the existing slab before laying a new floor, but that only helps if the board is thick enough to matter; the foil facing reduces the radiant exchange between the floor and the slab by a small amount.
A sheet slipped under a floor without a cavity does essentially nothing.
The practical retrofit is to add insulation and a vapor retarder above the slab, not to slide foil underneath. A rigid foam layer with a foil facing might be the right product here if you're already adding a floor assembly and want a combined insulation and vapor profile — but you need a cavity or substantial foam thickness for the foil's emittance to register.
Anyone retrofitting a floor over a cold slab should prioritize continuous rigid board of the appropriate thickness and a moisture strategy, then treat the shiny surface as a small bonus.
For an existing slab that's already got a crawl space beneath it with a ventilation gap, a foil barrier facing the warm side can help in cooling season. Keep that cavity clean and open; a foil surface clogged with debris or buried in insulation has lost the air space it needs.
What the vapor, moisture and code picture looks like
A radiant barrier in a slab assembly is now often part of a code-driven vapor retarder strategy. Many jurisdictions require a vapor retarder under a slab on grade, and the product is frequently a foil-faced membrane or a foil-faced foam board serving both roles. The performance you should credit to it is moisture control and, when there's a cavity, radiant resistance.
Two checks keep you honest. First, confirm what the product's labels actually claim: emittance, perm rating and whether it's rated as a vapor retarder and for below-grade use. Foil-backed rigid foams have published perm ratings that vary widely by facer. Second, confirm that the assembly can dry.
Adding a low-permeability foil to both sides of an insulation layer, or placing the foil where it will trap moisture, is a known failure mode; the barrier solves one problem and creates another unless the direction of vapor flow in that climate is considered.
For the actual code text, check the adopted model code for your jurisdiction (IECC or your local equivalent) and any local amendment, plus the manufacturer's installation guide for the specific board or membrane. Those documents define the allowed position, slopes, lapping and fastening; a general rule is no substitute for them.
Common installation failures to check
The most costly mistake isn't choosing the wrong product — it's a barrier that has the right product and the wrong geometry.
- No air space. Foil bonded directly to the slab with no cavity cannot resist radiant heat; it can only act as a facing or a moisture layer. Verify the assembly drawing shows the cavity.
- Air space filled with soil or gravel. A barrier whose cavity is backfilled has become a plain membrane.
- Foil on both faces of a wet-prone assembly. That's a moisture trap in the making.
- Lapped joints untreated. For a vapor-retarder role, laps and penetrations must be sealed with compatible tape or sealant; a foil membrane with open laps isn't a vapor barrier.
- Wrong face direction in a framed cavity. Low-emittance surfaces should face the warm side for the mechanism to help; verify against the assembly's intended heat flow direction.
- Assumed R-value from foil alone. If your decision rests on a claimed resistance, get the assembly's tested or specified resistance, not the foil's emittance.
If you're choosing a product for an above-slab or under-slab application, confirm that the specific facer has a documented perm rating and that the board or membrane is rated for below-grade use by its manufacturer. A product that is a good attic radiant barrier may be a poor under-slab choice.
FAQ
Can I use radiant barrier directly under concrete?
You can place a foil-faced vapor retarder on the granular fill before pouring, but the foil does not create an air space once the concrete is on it. Use it as a vapor retarder and moisture control layer, not as an insulating network. The insulation, if needed, is separate rigid foam or another rated layer.
Does a radiant barrier add R-value to a floor over a slab?
Only where there's an air space and the heat flow is radiant. Foil-faced rigid board adds R-value because of the foam thickness, not the foil. The foil's emittance reduces radiant exchange in a cavity; it doesn't create resistance without an air space.
Which climate gets more benefit?
Cooling-dominated climates gain more from a low-emittance surface facing downward heat, especially in a vented floor or crawl space. In heating-dominated climates the benefit is smaller and the vapor control function is often what matters. Don't expect a radiant barrier to replace insulation in either climate.
Where can I find the required position for my assembly?
The adopted code for your jurisdiction and the specific product's installation guide. Check the guide's allowed positions, whether the product is rated as a vapor retarder, and the required lapping; follow the local building code where it conflicts.